A certificate of analysis is only useful if you know what each line means, which results it actually proves, and how to confirm the document came from the lab named on it.
A certificate of analysis (COA) is a report issued by a testing laboratory describing what it found when it analyzed one specific sample. For research peptides, that usually means some combination of three things: whether the material is the compound it claims to be (identity), how clean it is (purity), and how much of it is present (quantity or net content).
A COA is not a marketing document, a product spec sheet, or a guarantee about every vial a supplier has ever sold. It describes one sample from one lot, tested on one date, by one method. Reading it well means checking that each of those details lines up with the material in front of you.
At NovaForge, every lot is tested by an independent US laboratory before release, and every COA is tied to a single lot. You can browse them on the COA registry or look up your own lot on the lot verification page.
Start at the top. A legitimate COA identifies the issuing laboratory by name, usually with an address, contact details, and a logo. It should also name the client who submitted the sample, which is typically the supplier.
Many labs list an accreditation or quality standard in the header or footer. If one is listed, note it and confirm it with the accrediting body or the lab itself rather than taking the badge at face value. If none is listed, that is not automatically a problem, but it means the lab's reputation and its willingness to confirm the report carry more weight.
Ask yourself one simple question here: could I contact this lab tomorrow and ask about this report? If the answer is no, the rest of the document matters less.
The sample block is where many weak COAs fall apart. Look for:
At NovaForge the lot number is not printed on the vial. It appears in your order-confirmation email, and entering it on /lot-verification returns the matching COA. For a fuller explanation of how lots work, see peptide lot numbers explained.
The method section tells you how the lab reached its numbers. For purity, this is almost always reversed-phase HPLC with UV detection, typically somewhere around 214 to 220 nm, where peptide bonds absorb. Some reports list the column, mobile phases, and gradient; others just name the technique.
The chromatogram is the graph that shows detector signal over time. A clean sample shows one dominant peak with small or no secondary peaks. The lab integrates the area under each peak, and the main peak's share of the total becomes the purity figure.
A COA that reports a purity number with no chromatogram, or with a chromatogram that has been cropped so the baseline and minor peaks are not visible, gives you less to evaluate. The graph is the evidence; the percentage is the summary.
The table below is an illustrative example of how a typical result reads, using the kind of layout and values found on our lot reports. It is not a copy of any single certificate.
| Field | Example entry | What it tells you |
|---|---|---|
| Laboratory | Freedom Diagnostics | Who ran the test and who can confirm it |
| Sample / report ID | Unique lab number | The reference you give the lab when verifying |
| Compound and label claim | BPC-157, 10 mg | What the vial is supposed to contain |
| Lot number | Supplier lot code | Must match the lot on your order |
| Identity method | LC-MS | Mass spectrometry confirms molecular identity |
| Identity result | Observed mass consistent with theoretical (about 1419.5 Da); pass | The molecule is what the label says |
| Purity method | HPLC-UV, about 214 nm | How cleanliness was measured |
| HPLC purity | 99.78% | Main peak share of UV signal; NovaForge does not release lots below 99% |
| Net content | Measured mg per vial | How much compound is actually present versus the label claim |
| Report date | Date issued | Should fit the lot's release timeline |
Different labs report different subsets. ILS Laboratories, for example, confirms identity by matching HPLC retention time to a reference standard and reports HPLC purity, while Freedom Diagnostics reports LC-MS identity, HPLC purity, and net content in mg. Both approaches are valid; they simply answer slightly different questions. For the difference between purity and quantity, read HPLC purity vs net peptide content.
Most problems with COAs are visible on the page if you know where to look:
One red flag is a reason to ask questions. Several together are a reason to look elsewhere. Our guide on how to verify a peptide vendor covers the wider checklist.
The strongest check is going to the source. The process is simple:
Some labs offer a verification code or online lookup. Janoshik Analytical, for instance, prints a code on its reports that can be checked on janoshik.com. Others confirm by email.
NovaForge COAs have been checked this way by outside reviewers: in October 2026, Prof. Peptide verified our certificates against ILS Laboratories and Freedom Diagnostics records. If you want to see the whole picture rather than one report at a time, our lab results dataset publishes all 26 COAs as a downloadable CSV under CC BY 4.0, with a median HPLC purity of 99.78%. For more on the different types of labs, see peptide testing labs explained.
The lot number and the lab's ability to confirm the report matter most, because they link the results to your material. After that, look at the identity result and the chromatogram. A high purity number means little if the report belongs to a different batch or cannot be traced back to the lab that supposedly produced it.
No. HPLC purity measures how much of the UV signal comes from the main peak. It does not by itself prove which molecule that peak is. Identity is confirmed separately, usually by LC-MS comparing observed mass to the theoretical mass, or by matching retention time against a reference standard.
The lot number is in your order-confirmation email, not printed on the vial. Enter it on the lot verification page at novaforgelabs.co/lot-verification and the matching certificate of analysis will appear. You can also browse every published report on the COA registry page.
Labs offer different test panels. Some report only identity and HPLC purity, while others add a quantity measurement in milligrams. Net content is a separate analysis from purity, so a report without it simply did not include that test. It does not mean the result was hidden.
A COA is relevant to the lot it describes, regardless of age, as long as that lot is what you received. The concern is an old report being used to represent newer batches. Check that the report date fits the lot's production and release timeline.
HPLC Purity vs Net Peptide Content: Why 99% Pure Isn't 100% PeptidePeptide Lot Numbers ExplainedJanoshik vs Finnrick vs Other Peptide Testing Labs, ExplainedHow to Tell If a Research Peptide Vendor Is LegitThird-Party Tested Research PeptidesLab results dataset
Browse third-party tested research materials →